--- title: "APPENDINCES" slug: "appendinces-1" updated: 2024-02-15T09:12:26Z published: 2024-02-15T09:12:26Z canonical: "support.keypro.fi/appendinces-1" excludeFromSearch: true excludeFromExternalSearch: true --- > ## Documentation Index > Fetch the complete documentation index at: https://support.keypro.fi/llms.txt > Use this file to discover all available pages before exploring further. # APPENDINCES ## Map symbols | Cable | ![com_kuvat/karttasymbolit/kaapeli.bmp](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-e0alf4fm.png) | | --- | --- | | Conduit | ![com_kuvat/karttasymbolit/kanava.bmp](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-nc861mfq.png) | | Splice | ![com_kuvat/karttasymbolit/jatkos.bmp](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-u44l6t2r.png) | | Telecom premises | ![](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-qzy3azcn.png) | | Pole | ![com_kuvat/karttasymbolit/pylvas.bmp](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-ayivhn8c.png) | | Manhole | ![](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-dn596u9x.png) | | Address | ![com_kuvat/karttasymbolit/osoite.bmp](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-s5hu95fm.png) | | Radio link | ![com_kuvat/karttasymbolit/radiolinkki.bmp](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-yeqw4gf0.png) | | Point object | ![](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-6mrq4pyu.png) | ## Device database forms ![](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-hy6zf1pf.png) ![](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-kcf9yfdx.png) ![](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-09mnkhl7.png) ![](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-g26eyfa4.png) ![](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-gq7s3rzz.png) ![](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-4ye87m7w.png) ![](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-0h23y12c.png) ![](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-o2pz34fx.png) ![](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-utf8kydb.png) ![](https://cdn.document360.io/672fb328-110d-4b2d-9d5f-f1e71883bb64/Images/Documentation/appendices-image-w3c82s1g.png) ## Backup circuit ruleset When linking a backup circuit, you can use various predetermined rulesets. These environment-specific rulesets can be configured in the [Circuit backup rule manager.](/docs/appendinces-1#_Managing_circuit_backup) **Default rulesets that can be activated:** ### **No same premises** This ruleset specifies whether any telecom premises between the compared circuits can be the same. **Notable features:** - The user receives a notice if there are same telecom premises reserved for both circuits compared (primary and backup circuits) either in the logical or physical reservations. - It is possible for the user to see conflicting telecom premises on the list. You can see the ID, name, and type of the conflicting item. - The user has the option to open conflicting components of the circuit reservations on a group display list. - If no type of telecom premises has been selected, the comparison will be made regardless of the type of the telecom premises. **Distance value:** - The required distance in meters. - Consider only the types of telecom premises specified in the field. - If the locations of the reserved telecom premises for comparable circuits are closer than the specified distance value, the user will be notified when saving the circuits. - Conflicted telecom premises can be viewed on the list. The user has the option to open conflicting components of the circuit reservations on a group list. ### **Not same devices** This ruleset determines whether any device between the circuits compared can be the same. **Notable features:** - For example, customers device (CPE) or backbone router can be focused on a certain device type and considered this way. - If no type of telecom premises has been selected, the comparison will be made regardless of the type of the telecom premises. - The user receives a notice if there are same devices reserved for both circuits compared (primary and backup circuits) either in the logical or physical reservations. - Information about the conflicted devices can be viewed on a group list. This information includes the ID, name, and type of the device. ### **Not same connectors** For example, the customer connector device can be the same, but the gate has to be different than the local loop. **Notable features:** - The user receives a notice if there are same connectors reserved for both circuits compared (primary and backup circuits) either in the logical or physical reservations. - Information about the conflicted connectors can be viewed on a group list. This information includes the ID, name, and type of the device. ### **Not same cables** The circuits compared cannot have the same cables. **Notable features:** - If no type of cable role has been selected, the comparison will be made regardless of the role type of the cable. - The user receives a notice if there are same cables reserved for both circuits compared (primary and backup circuits) either in the logical or physical reservations. - Information about the conflicted devices can be viewed on a group list. This information includes the ID, name, and type of the device. **Distance values**: The backup circuit cannot use the cables of the local loop and the distance between these must be at least n meters. - Required distance value in meters. - Consider only the types of cables specified in the field. - If the locations of the cables for comparable circuits are closer than the given distance value, the user will be notified when saving the circuits. - Information about the conflicted cables can be viewed on a group list. This information includes the ID, name, and type of the device. - Conflicting cables on the list (ID, role, and type), and the option to show the conflicting components of an allocated connection on a group list [OK/Show grouplist options]? ### **Not same threads** **Notable features:** - The user receives a notice if there are same threads reserved for both circuits compared (primary and backup circuits) either in the logical or physical reservations. - Information about the conflicted cables can be viewed on a group list. This information includes the ID, name, and type of the device.