Create new Dh Meter Reading
  • 17 Jan 2024
  • 1 Minute to read
  • Contributors
  • Dark
    Light
  • PDF

Create new Dh Meter Reading

  • Dark
    Light
  • PDF

Article summary

Post
/dh-meter-reading/
Security
API Key
Header parameter nameAuthorization

Token issued for API consumer.

Body parameters

Dh Meter Reading to be created

object
DhMeter
integer Required

DH Meter ID

comments
string

Comments

consumption_estimate
integer

Consumption estimate

id
integer

Primary key

in_water_temp
number (float)

In water temperature

modifier_q
integer

Parameter use for computing dh consumption

modifier_qntp
integer

Parameter use for computing dh consumption

out_water_temp
number (float)

Out water temperature

power
integer

Power

reading
integer Required

DH meter reading

reading_date
string (date) Required

Reading date

removed
integer

Flag for removed status

save_date
string (date)

Save date

save_user
string

Save user

thermal_energy
integer

Thermal energy

water_circulation
integer

Water circulation

water_cooling
number (float)

Water cooling

water_flow
number (float)

Water flow

Responses
201

A created Dh Meter Reading

{
  "DhMeter": [
    "5032"
  ],
  "comments": [
    "test comment"
  ],
  "consumption_estimate": [
    "300"
  ],
  "id": [
    "123"
  ],
  "in_water_temp": [
    "27"
  ],
  "modifier_q": [
    "123"
  ],
  "modifier_qntp": [
    "123"
  ],
  "out_water_temp": [
    "30"
  ],
  "power": [
    "23.4"
  ],
  "reading": [
    "50"
  ],
  "reading_date": [
    "08/06/2021 00:00:00"
  ],
  "removed": [
    "1"
  ],
  "save_date": [
    "08/06/2021 00:00:00"
  ],
  "save_user": [
    "test_user"
  ],
  "thermal_energy": [
    "123"
  ],
  "water_circulation": [
    "123"
  ],
  "water_cooling": [
    "123"
  ],
  "water_flow": [
    "1234"
  ]
}
object
DhMeter
integer

DH Meter ID

comments
string

Comments

consumption_estimate
integer

Consumption estimate

id
integer

Primary key

in_water_temp
number (float)

In water temperature

modifier_q
integer

Parameter use for computing dh consumption

modifier_qntp
integer

Parameter use for computing dh consumption

out_water_temp
number (float)

Out water temperature

power
integer

Power

reading
integer

DH meter reading

reading_date
string (date)

Reading date

removed
integer

Flag for removed status

save_date
string (date)

Save date

save_user
string

Save user

thermal_energy
integer

Thermal energy

water_circulation
integer

Water circulation

water_cooling
number (float)

Water cooling

water_flow
number (float)

Water flow

400

There was an error in request. Usually field validation failed.

{
  "reading": [
    "This field is required."
  ],
  "reading_date": [
    "This field is required."
  ]
}

Fields which failed validation

401

Authentication credentials are missing or invalid

{
  "details": "Authentication credentials were not provided"
}
object
details
string

Detailed description of error


Was this article helpful?