2026-10-23 12.00 UTC - There are currently no active events. All systems operational.

Mass update the sewer ducts of one CCTV inspection file

Prev Next
Post
/tv-inspection/mass-update/

Queues a background update of the sewer duct linked to every inspection imported from the named file, except the ones with mass_update_disabled. For each inspection the first observation's dimension and material re-point the duct to the matching duct type, its form sets the duct profile when the observation has one, and its dimension and material determination codes are stored on the duct. An inspection without a linked duct is skipped, and one whose values match no duct type is reported in errors; no duct type is created. Poll the result with the mass update status endpoint.

Security
API Key: Token
Header parameter nameAuthorization

Token issued for API consumer.

Body parameters
object
source_filename
string Required

Name of the XML file the inspections were imported from.

Responses
202

The mass update is queued.

object
processingStatus
string
Valid values[ "pending" ]
taskId
string
400

source_filename is missing or invalid.

401

Authentication credentials were not provided or are invalid.

403

The user may not view CCTV inspections or change sewer ducts.

404

No CCTV inspections were imported from this file.