2025-11-06 14.00 UTC - There are currently no active events. All systems operational.

KeyCom 2026.1 Release notes

Prev Next

Foreword:

This document describes new and noteworthy features added to KeyCom’s latest version. Some features are subject to additional activation/order even if it is not mentioned explicitly, contact us for more details. Please note that the features and their functionalities are subject to change, and they can be removed or changed in the future releases.


2026.1

Automatic route search for physical networks (this function is subject to a separate activation)

  • Included a drop-down menu in the Automatic route search form for selecting a proper routing method

  • Added the ability to fetch all topologically connected conduit and cable routes between defined source and destination objects, ranked by shortest distance, fewest objects, and alternative paths

  • Included three tabs for the physical network method: Route search, Objects to avoid, and Mandatory objects:

    • The Route search tab includes options to define source and destination objects, set maximum routes, length, and object count, and apply filters like Free of cables and search buffer to focus on specific areas

    • The Objects to avoid tab allows specifying network objects to exclude, with search and selection options

    • The Mandatory objects tab enables defining required objects along the route, with search and selection options

  • Added grids to display available routes and route’s connections with details in the Route search tab

New Cable types list feature

  • Added a new Cable types list under the Cable drop-down menu in KeyCom tools

  • Created a list view for all available cable types along with their color configuration definitions

  • Added filtering options based on column data

  • Added the ability to generate a list report containing cable type information

Enhancements to Cross-section form device management

  • Introduced a new Device management… drop-down menu in the Devices / Cables list, providing access to device operations. The menu includes:

    • Delete device with sub-devices – Remove a device along with its entire hierarchy directly from the context menu

    • Copy device – Duplicate a device and its sub-devices

    • Add sub-device – Create new devices within the existing hierarchy using the Device form, automatically initialized with correct telecom premises and parent device

    • Move device with sub-devices – Relocate a device and its hierarchy within the Cross-section form, with confirmation required before completing the move

  • Enhanced Checking device tree pop-up notifications for device actions to display detailed lists of related devices and connectors blocking deletion or movement, with context menus and an option to open affected circuits

  • Improved the Refresh button in the Cross-section form to retain focus on the selected device, cable, connector, or thread after refreshing

Enhancements to ViVi/FICORA report

  • Renamed the ViVi/FICORA report to Traficom availability information, including updated translations for all supported languages

  • Added a new default Technology option CTV/Fiber, representing setups where cable TV (CTV) is used internally and fiber enters the home

  • Extended the report to include new columns: NDL and NUL

Enhancements to the Faulty components detected form

  • Renamed the form from Faulty components detected to Components requiring special attention to better reflect its purpose

  • Added a new context‑menu option that opens the Connections management form when faulty connections are detected

Enhancements to Address alias functionality

  • Added Created by, Created at, Updated by and Updated at columns to the Address form list and also included them as fields in the Address alias form

Other new features and enhancements

  • Improved the performance of the Devices tab in the Telecom premises form and added a loading indicator to show when the device list is still being retrieved

  • Expanded circuit and circuit section details to include new fields (Created By, Created At, Updated By and Updated At) in forms and lists

  • Added a button in the Circuit form to open Change history and enhanced the view to include changes for related objects such as sections, physical reservations, and logical reservations

  • Introduced Super circuit form to group multiple circuits under one structure, providing summarized data with list reports, export, and locate/highlight tools for better management of networks (this function is subject to separate activation)

  • Added a new Use Geoid height correction checkbox to the KeyMobile V1 Survey settings page (this function is subject to separate activation)

PostgreSQL compatibility

  • Added Work order report for selected feature to handle multiple circuits at once via Circuit report service

Rest API

  • Improved security for the txt constants API to ensure sensitive data is protected and editing permissions are limited to authorized users only

  • Added API endpoints for the new Super circuit model and updated existing Circuit model to include Super circuit information

  • Updated API to include Created by, Created at, Updated by and Updated at information for circuit-related objects

  • Added JWT authentication to all API views

  • Implemented CRUD REST API support for PrintOutSeries, PrintOutFrame, and PrintoutLegend to enable management of printout configurations